The Definitive Guide toAI Data Centers
Ask the GuideAboutAccount
Guide › Numbers register › Claim

PTP accuracy across an NVIDIA Spectrum-3 switch acting as a boundary clock (vendor test: one hour, 50 Gb/s, IXIA leader/follower; vendor states it holds across link speeds and FEC configurations)

~10 nsobserved

Value kindobserved — Reported measurements, counts, and specifications keep the precision and scope stated by their source; an exact specification is not treated as a range.
ScopeEnd-to-end PTP accuracy across the switch. The sub-4 ns figure is a different quantity, the synchronization error between hardware units inside the Spectrum ASIC, and has its own register entry. Do not read it off this tile.
As of2022-09
SourceNVIDIA Technical Blog, 'Calculating and Synchronizing Time with the Precision Timing Protocol on the NVIDIA Spectrum Switch' (developer.nvidia.com, 2022) · PTP accuracy section: about 10 ns from a one-hour, 50 Gb/s test with IXIA as leader and follower; NVIDIA states the accuracy holds across speeds and FEC configurations
Reviewchecking…review by 2027-04-16 · standard cadence
Recorded changeslast 2026-09-16 · 3 revisions tracked
Claim idptp-accuracy-held-across-a-spectrum-switch

Where the guide uses it

← Full numbers register — every date-stamped figure in the guide, with revision history.