Indicative OEM heat rates: simple-cycle aeroderivatives versus large frame-based combined cycle, natural gas at ISO conditions

~8–9 vs ~5–6 MMBtu/MWh (LHV)estimate

Value kindestimate — Interpret this value according to its displayed kind, scope, source, and as-of date.
ScopeThese are rounded OEM ratings, not measured fleet performance. The LM6000 in simple cycle rates about 8.3–8.6 LHV and the 7HA.03 in combined cycle about 5.3 LHV; a compact LM6000 combined cycle rates about 6.2–6.6 LHV. Fuel cells are excluded. Before you cost the fuel, convert to the basis your gas price is contracted on, and include project auxiliaries in the site heat rate.
As of2025-10
SourceGE Vernova, Gas Power Products and Services catalog (GEA35241), October 2025
Reviewchecking…review by 2027-01-13 · standard cadence
Recorded changeslast 2026-10-13 · 3 revisions tracked
Claim idfuel-burn-simple-cycle-turbine-vs-combined

Where the guide uses it